Mobile Endoscopy Unit — GI Mobile Clinic by Odulair

Odulair · Mobile Clinic Systems · Joelton, TN

Mobile Endoscopy Unit

Odulair engineers mobile endoscopy units for gastroenterology programs, colorectal cancer screening initiatives, and hospital outreach — procedure room, reprocessing, and recovery on a 30ft or 53ft platform.

CAGE 6L2X9
·UEI LUAKV3T8KSV5
·WOSB · SAM.gov Active
·50-Day Lead Time
·DOT/NHTSA Certified · WMI 1Z9
Platform
Hino L7 30ft (NON-CDL) · 53ft Trailer (CDL)
Endoscopy Systems

Full GI Procedure Suite — Mobile

Procedure Room

Endoscopy procedure table · Suction/irrigation · Medical gas (O₂/vacuum) · LED endoscopy lighting · Monitor boom provision · Privacy partition

Scope Reprocessing

AER (automated endoscope reprocessor) provision · Sink station · Scope storage · SGNA/AAMI ST91 compliant workflow

Recovery Zone

2–4 recliner recovery positions · Patient monitoring provision · Nurse call · IV pole provision · Privacy curtains

Patient Flow

Check-in / intake · Prep area · Procedure room · Recovery · Discharge — complete one-way clinical workflow

Compliance

SGNA guidelines · AAMI ST91 · NFPA 99 medical gas · NEC 517 electrical · ADA accessible

Power

Shore power + generator · Uninterruptible AER circuits · Medical-grade isolated circuits

FAQ

Frequently Asked Questions

What procedures can be performed in a mobile endoscopy unit?

Mobile endoscopy units support upper GI endoscopy (EGD), colonoscopy, flexible sigmoidoscopy, and related diagnostic procedures. They are widely used for colorectal cancer screening programs, community health outreach, and hospital satellite GI services.

What platform is best for a mobile endoscopy unit?

The 30ft Hino L7 NON-CDL is the most popular choice — it accommodates a procedure room, reprocessing area, and 2-position recovery in a clinically compliant layout. For higher-volume programs or multi-room configurations, the 53ft double-expandable trailer provides ~1,000 sq ft with full scope reprocessing capability.

Does a mobile endoscopy unit require specialized reprocessing equipment?

Yes. SGNA guidelines and AAMI ST91 require automated endoscope reprocessing (AER). Odulair integrates AER units (Medivators, Olympus, or equivalent) with dedicated sink stations, scope storage, and compliant water systems. Scope reprocessing is included in the standard mobile endoscopy configuration.

Request Specifications & Pricing

Odulair LLC · WOSB · CAGE 6L2X9 · Joelton, TN · 50-Day Lead Time

info@odulair.com · Van configurations →